Domestic activated carbon filters dusting
Anita Staroń
Jolanta Pulit
Marcin Banach
Michał Zielina
Wojciech Dąbrowski
  
Keywords: activated carbon, bacteria, home potable water filters, refrigerators
Abstract
Some difficulties with positive evaluation of bacteriological content of water treated using the process of adsorption on
granular activated carbon have been stressed. The problem arises if the number of bacteria extracted from the coal dust
particles is accounted. Some small coal particles are continuously releasing for the whole period of filters operation.
According to the literature review in the last years the microorganisms content of coal fines caused Japanese engineers
more often constructing sand filters not before, but after, GAC adsorbent filters and building sandwich slow filters. Based on
own observations of filters applied in households to treating potable water it was suggested that the filtrate should be also
protected against GAC particles. Laboratory tests confirmed that these filters also release coal fines even from the cartridge
of agglomerated activated carbon. In conclusion it was suggested that for the drinking water microbiological safety the coal
filters should be removed from the filtrate.
 

Redakcja GAZ WODA I TECHNIKA SANITARNA
Siedziba redakcji: ul. Czackiego 3/5, pok.404, 00-043 Warszawa
tel./fax 0 22 827 02 49 tel. 22 336 14 07, www.gazwoda.pl
e-mail: gwits@poczta.onet.pl, gazwoda@sigma-not.pl

Wydawnictwo SIGMA-NOT Sp. z o.o.
ul. Ratuszowa 11, 00-950 Warszawa, skr. poczt. 1004
Sąd Rejonowy dla m.st. Warszawy, XIII Wydział Gospodarczy, KRS: 0000069968
NIP
: 524 030 35 01
Kapitał zakładowy: 752 361,80 zł 

Na naszej witrynie wykorzystujemy pliki cookies w celu realizacji usług oraz gromadzenia informacji związanych z korzystaniem ze strony.

Plikami cookies możesz zarządzać w opcjach przeglądarki, z której korzystasz. Więcej informacji znajdziesz tutaj.